PV self-consumption
What this case shows
- An unrestricted sink's provenance row is the raw source mix.
- PV standby is a sink drawing from the mix, not negative production.
- Marginal cost and levelized cost diverge as soon as a local source runs.
- A source that only draws standby makes the saving rate negative.
Each snapshot below is one set of readings on this wiring, drawn as a flow chart — how to read it.
Sunny, partial
Grid and PV system both supplying; the base load takes them in proportion.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 1400 W | 1 | grid 800 W · pv1 600 W | |
| Grid import | 800 W | 4/7 | grid 800 W | |
| Grid export | 0 W | 0 | nothing exported | |
| PV production | 600 W | 3/7 | pv1 600 W | |
| Charging power | 0 W | 0 | no battery charging | |
| Discharging power | 0 W | 0 | no battery discharging | |
| Standby power | 0 W | 0 | no standby draw | |
| Self-consumption | 1400 W | 1 | grid 800 W · pv1 600 W | |
| Metering imbalanceok | 0 W | 0 | readings reconcile exactly | |
| Home base load | 1400 W | 1 | unmetered remainder of consumption |
PV covers all
The PV system covers the house exactly. The grid is present but contributes nothing.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 600 W | 1 | pv1 600 W | |
| Grid import | 0 W | 0 | nothing drawn from the grid | |
| Grid export | 0 W | 0 | nothing exported | |
| PV production | 600 W | 1 | pv1 600 W | |
| Charging power | 0 W | 0 | no battery charging | |
| Discharging power | 0 W | 0 | no battery discharging | |
| Standby power | 0 W | 0 | no standby draw | |
| Self-consumption | 600 W | 1 | pv1 600 W | |
| Metering imbalanceok | 0 W | 0 | readings reconcile exactly | |
| Home base load | 600 W | 1 | unmetered remainder of consumption |
PV standby
pv1 draws 20 W standby, so it is a sink served by the grid — and the saving goes negative.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 1000 W | 1 | grid 1000 W | |
| Grid import | 1000 W | 1 | grid 1000 W | |
| Grid export | 0 W | 0 | nothing exported | |
| PV production | 0 W | 0 | no PV system | |
| Charging power | 0 W | 0 | no battery charging | |
| Discharging power | 0 W | 0 | no battery discharging | |
| Standby power | 20 W | 1/50 | pv1 20 W | |
| Self-consumption | 980 W | 49/50 | grid 980 W | |
| Metering imbalanceok | 0 W | 0 | readings reconcile exactly | |
| Home base load | 980 W | 49/50 | unmetered remainder of consumption |
PV unavailable
The PV system's sensor has dropped out; the grid still reads, but the total cannot be trusted.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | unavailable | — | not published: a reading is unavailable | |
| Grid import | 1000 W | — | grid 1000 W | |
| Grid export | 0 W | — | nothing exported | |
| PV production | unavailable | — | not published: a reading is unavailable | |
| Charging power | 0 W | — | no battery charging | |
| Discharging power | 0 W | — | no battery discharging | |
| Standby power | unavailable | — | not published: a reading is unavailable | |
| Self-consumption | unavailable | — | not published: a reading is unavailable | |
| Metering imbalance | unavailable | — | not published: a reading is unavailable | |
| Home base load | unavailable | — | not published: a reading is unavailable |
Why this case exists
This is the first case with a choice in it. Two sources are supplying one sink, and the engine has to say in what proportion — the answer being the raw availability of the sources, with no restriction anywhere to complicate it. Every restricted case later in the ladder is a departure from exactly this, and if the tiered logic in the solver is working, this is what it must collapse to when there is nothing to tier.
Two sources are also the minimum for the money layer to say anything
interesting. With the grid alone, what power costs now and what it costs
levelized are the same number. Add a PV system and they come apart: coe falls as
the free fuel displaces the tariff, while lcoe carries the PV system's capital
cost whether or not the sun is out.
The standby snapshot is the sharpest thing here. A PV system drawing 20 W is not producing −20 W — it is a sink, and it is served from the grid like any other. Which means the saving rate goes negative: at that instant the solar installation is costing its owner money.