PV self-consumption

One PV system added to the grid, and nothing restricted. Two sources are enough for the raw proportional mix, for the divergence between what power costs now and what it costs levelized, and for a PV system that is drawing rather than producing.

What this case shows​

  • An unrestricted sink's provenance row is the raw source mix.
  • PV standby is a sink drawing from the mix, not negative production.
  • Marginal cost and levelized cost diverge as soon as a local source runs.
  • A source that only draws standby makes the saving rate negative.

Each snapshot below is one set of readings on this wiring, drawn as a flow chart — how to read it.

Sunny, partial​

PV self-consumption · snapshot 01

Grid and PV system both supplying; the base load takes them in proportion.

SOURCESCHANNELSSINKS
ReadingWOf grossShareMade of
Gross power1400 W1grid 800 W · pv1 600 W
Grid import800 W4/7grid 800 W
Grid export0 W0nothing exported
PV production600 W3/7pv1 600 W
Charging power0 W0no battery charging
Discharging power0 W0no battery discharging
Standby power0 W0no standby draw
Self-consumption1400 W1grid 800 W · pv1 600 W
Metering imbalanceok0 W0readings reconcile exactly
Home base load1400 W1unmetered remainder of consumption
Ribbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

PV covers all​

PV self-consumption · snapshot 02

The PV system covers the house exactly. The grid is present but contributes nothing.

SOURCESCHANNELSSINKS
ReadingWOf grossShareMade of
Gross power600 W1pv1 600 W
Grid import0 W0nothing drawn from the grid
Grid export0 W0nothing exported
PV production600 W1pv1 600 W
Charging power0 W0no battery charging
Discharging power0 W0no battery discharging
Standby power0 W0no standby draw
Self-consumption600 W1pv1 600 W
Metering imbalanceok0 W0readings reconcile exactly
Home base load600 W1unmetered remainder of consumption
Idle: grid · 0 WRibbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

PV standby​

PV self-consumption · snapshot 03

pv1 draws 20 W standby, so it is a sink served by the grid — and the saving goes negative.

SOURCESCHANNELSSINKS
ReadingWOf grossShareMade of
Gross power1000 W1grid 1000 W
Grid import1000 W1grid 1000 W
Grid export0 W0nothing exported
PV production0 W0no PV system
Charging power0 W0no battery charging
Discharging power0 W0no battery discharging
Standby power20 W1/50pv1 20 W
Self-consumption980 W49/50grid 980 W
Metering imbalanceok0 W0readings reconcile exactly
Home base load980 W49/50unmetered remainder of consumption
Ribbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

PV unavailable​

PV self-consumption · snapshot 04

The PV system's sensor has dropped out; the grid still reads, but the total cannot be trusted.

pv1 has no reading, so the engine publishes no flows for this snapshot.
SOURCES
ReadingWOf grossShareMade of
Gross powerunavailable—not published: a reading is unavailable
Grid import1000 W—grid 1000 W
Grid export0 W—nothing exported
PV productionunavailable—not published: a reading is unavailable
Charging power0 W—no battery charging
Discharging power0 W—no battery discharging
Standby powerunavailable—not published: a reading is unavailable
Self-consumptionunavailable—not published: a reading is unavailable
Metering imbalanceunavailable—not published: a reading is unavailable
Home base loadunavailable—not published: a reading is unavailable
Ribbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

Why this case exists​

This is the first case with a choice in it. Two sources are supplying one sink, and the engine has to say in what proportion — the answer being the raw availability of the sources, with no restriction anywhere to complicate it. Every restricted case later in the ladder is a departure from exactly this, and if the tiered logic in the solver is working, this is what it must collapse to when there is nothing to tier.

Two sources are also the minimum for the money layer to say anything interesting. With the grid alone, what power costs now and what it costs levelized are the same number. Add a PV system and they come apart: coe falls as the free fuel displaces the tariff, while lcoe carries the PV system's capital cost whether or not the sun is out.

The standby snapshot is the sharpest thing here. A PV system drawing 20 W is not producing −20 W — it is a sink, and it is served from the grid like any other. Which means the saving rate goes negative: at that instant the solar installation is costing its owner money.