Skip to main content
Version: 2026.11

Metered load

A consumer with a meter on it, next to the unmetered remainder. The base load stops being the whole house and becomes what is left after the metered draw — including when the meters disagree and there is nothing left.

What this case shows​

  • A metered consumer gets its own provenance row; the remainder is the home base load.
  • A metered draw larger than what the sources supply is balanced by meeting in the middle: the sources move up, the load moves down, and the base load is exactly zero.
  • A zeroed base load still publishes a share row, of zeros.

Each snapshot below is one set of readings on this wiring, drawn as a flow chart — how to read it.

Load and base load​

Metered load · snapshot 01

cons1 draws 500 W of the 1400 W entering the house; the other 900 W is unmetered.

SOURCESCHANNELSSINKS
ReadingWOf grossShareMade of
Gross power1400 W1grid 800 W · pv1 600 W
Grid import800 W4/7grid 800 W
Grid export0 W0nothing exported
PV production600 W3/7pv1 600 W
Charging power0 W0no battery charging
Discharging power0 W0no battery discharging
Standby power0 W0no standby draw
Self-consumption1400 W1grid 800 W · pv1 600 W
Metering imbalanceok0 W0readings reconcile exactly
Home base load900 W9/14unmetered remainder of consumption
Ribbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

Over-metered​

Metered load · snapshot 02

cons1 reads 400 W while the sources supply 300 W — the meters were sampled at different moments. No meter is trusted over another: the grid and pv1 move up by 8/7 and cons1 down by 6/7, to about 343 W on both sides, and the 100 W gap is the metering imbalance.

SOURCESCHANNELSSINKS
ReadingWOf grossShareMade of
Gross power342.9 W1grid 100 W · pv1 200 W
Grid import100 W7/24grid 100 W
Grid export0 W0nothing exported
PV production200 W7/12pv1 200 W
Charging power0 W0no battery charging
Discharging power0 W0no battery discharging
Standby power0 W0no standby draw
Self-consumption342.9 W1grid 114.3 W · pv1 228.6 W
Metering imbalanceunexplained100 W7/24metered sinks drew more than the sources supplied; the engine balances the readings
Home base load0 W0unmetered remainder of consumption
100 W of the readings is not explained by the other meters (hatched); the ribbons follow the engine's balanced flows.Ribbon widths are watts in every view. Hover, focus or tap a ribbon to see the sensor behind it.

Why this case exists​

Up to this rung the home base load was the house. Putting a meter on one device splits it in two, and the interesting half is the one nobody measured: the base load is not read from anything, it is what is left when the metered draw is taken off the total.

Being derived is what makes it fragile, and the second snapshot is where it breaks. cons1 reports drawing 400 W while the sources between them supply only 300 W. No arrangement of real electrons does that — it is two sensors disagreeing, a scaling factor set wrong, or readings from different instants — and the engine has to publish something. It clamps: the base load floors at zero rather than going negative, and still publishes a share row, of zeros.

Whether a zero row is the right answer there, as against publishing nothing at all the way an unavailable sensor does, is a fair thing to disagree with. It is recorded here so the disagreement has somewhere to point.