PV export
What this case shows
- An exporting grid is a sink, not a source with a negative reading.
- Export compensation is earned by the sources the export was drawn from.
- Zero gross power guards to zero rather than dividing by zero.
Each snapshot below is one set of readings on this wiring, drawn as a flow chart — how to read it.
Export surplus
The PV system outruns the house; the surplus leaves through the grid.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 900 W | 1 | pv1 900 W | |
| Grid import | 0 W | 0 | nothing drawn from the grid | |
| Grid export | 400 W | 4/9 | pv1 400 W | |
| PV production | 900 W | 1 | pv1 900 W | |
| Charging power | 0 W | 0 | no battery charging | |
| Discharging power | 0 W | 0 | no battery discharging | |
| Standby power | 0 W | 0 | no standby draw | |
| Self-consumption | 500 W | 5/9 | pv1 500 W | |
| Metering imbalanceok | 0 W | 0 | readings reconcile exactly | |
| Home base load | 500 W | 5/9 | unmetered remainder of consumption |
Export all
Everything the PV system makes is exported: the home base load is exactly zero.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 900 W | 1 | pv1 900 W | |
| Grid import | 0 W | 0 | nothing drawn from the grid | |
| Grid export | 900 W | 1 | pv1 900 W | |
| PV production | 900 W | 1 | pv1 900 W | |
| Charging power | 0 W | 0 | no battery charging | |
| Discharging power | 0 W | 0 | no battery discharging | |
| Standby power | 0 W | 0 | no standby draw | |
| Self-consumption | 0 W | 0 | nothing consumed | |
| Metering imbalanceok | 0 W | 0 | readings reconcile exactly | |
| Home base load | 0 W | 0 | unmetered remainder of consumption |
Zero gross
The grid exports while nothing is producing — an impossible meter set that must not divide by zero.
| Reading | W | Of gross | Share | Made of |
|---|---|---|---|---|
| Gross power | 0 W | — | no source delivers anything | |
| Grid import | 0 W | — | nothing drawn from the grid | |
| Grid export | 500 W | — | nothing exported | |
| PV production | 0 W | — | pv1 0 W | |
| Charging power | 0 W | — | no battery charging | |
| Discharging power | 0 W | — | no battery discharging | |
| Standby power | 0 W | — | no standby draw | |
| Self-consumption | 0 W | — | nothing consumed | |
| Metering imbalanceunexplained | 500 W | — | metered sinks drew more than the sources supplied; the engine balances the readings | |
| Home base load | 0 W | — | unmetered remainder of consumption |
Why this case exists
Nothing is added here. The same two devices are wired the same way, with one configuration flag flipped, and that is the point — the whole export family turns on a permission rather than on a device.
Reversing the grid changes its kind, not just its sign. An importing grid is the largest source in the house; the same grid exporting is a sink, and the diagram moves it to the other side accordingly. Everything downstream follows from that one reclassification: the export channel takes a share of gross power, the compensation is credited to whichever sources fed it, and self-consumption is measured against what stayed home rather than against everything produced.
The last snapshot is a guard rather than a scenario. The grid exports 500 W while nothing at all is producing — a meter set that cannot physically happen, but that a dropped sensor or a bad scaling factor will hand the engine anyway. Gross power is exactly zero, and every ratio derived from it has to survive being asked.