Skip to main content
Version: 2026.7

Entity reference

This is the full list of sensors Power Insight can create, grouped by scope. Which sensors actually appear depends on the options you enable — see Sensors, presets & options.

Currency units

Sensors are documented in EUR for brevity. At runtime the EUR unit is replaced with your Home Assistant currency (e.g. $/h, £/kWh).

Entity names may change

Power Insight is in beta; entity names may change until 1.0.

info
ratio vs. share — they are not the same

Every percentage sensor is one or the other, and the denominator differs:

  • … ratio — a fraction of the scope's own power: for a device, its own production/throughput (e.g. Export ratio = the fraction of this PV system's production that is exported); for the whole home, gross power.
  • … share — this device's slice of a home-wide total (e.g. Export share = this system's exports ÷ all power exported by the home).

See Power distribution → ratio vs. share for the full definition.

Legend for the Enabled by column — the option/category (and where relevant the device capability) that must be on for the sensor to exist:

  • Distribution (W/ratios/shares) → the matching Power sensors category.
  • Cost — Standard / Levelized → the Cost calculation method.
  • Savings — Standard / Levelized → the Savings calculation method.
  • Financial return — Standard / Levelized → the Financial return method.
  • Accumulate … → the matching accumulate toggle.

Combined (whole home)​

These aggregate power and cost across your whole home — they sum all your devices into a single number per metric.

Real-time sensors​

SensorUnitMeaningEnabled by
Available powerWGross power entering the home (grid import + PV production + battery discharge). Diagnostic, disabled by default.Debug power entities
Combined self-consumption powerWLocally produced power (solar + battery discharge) your home is using right now instead of importing.Distribution (W)
Combined charging powerWPower currently going into battery charging.Distribution (W)
Combined standby powerWPower currently consumed by device standby (e.g. PV at night).Distribution (W)
Combined export ratio%Share of gross power currently exported to the grid.Distribution ratios
Combined self-consumption ratio%Share of gross power currently self-consumed.Distribution ratios
Combined charging ratio%Share of gross power currently going to charging.Distribution ratios
Combined standby ratio%Share of gross power currently lost to standby.Distribution ratios
Combined price of electricityEUR/kWhCurrent blended price of one kWh across your whole mix (grid + your devices).Cost — Standard
Combined levelized price of electricityEUR/kWhAs above, but each device's cost is its levelized lifetime cost.Cost — Levelized
Combined cost rateEUR/hRunning cost per hour of your current mix.Cost — Standard
Combined levelized cost rateEUR/hCost rate computed with levelized device costs.Cost — Levelized
Combined operating cost rateEUR/hRunning operating cost per hour of your mix.Cost — Standard
Combined levelized operating cost rateEUR/hOperating cost rate with levelized device costs.Cost — Levelized
Combined cost savings rateEUR/hMoney saved per hour by self-consuming your own generation — avoided grid import minus operating costs. Does not include export revenue.Savings — Standard
Combined levelized cost savings rateEUR/hCost savings rate computed with levelized device costs.Savings — Levelized
Combined financial return rateEUR/hTotal financial benefit per hour — cost savings plus export compensation.Financial return — Standard
Combined levelized financial return rateEUR/hFinancial return computed with levelized device costs.Financial return — Levelized

Accumulated totals​

SensorUnitMeaningEnabled by
Combined total operating costEUROperating cost rate integrated over time.Accumulate costs
Combined total levelized operating costEURLevelized operating cost totalled across all devices (retro-corrected).Accumulate levelized costs
Combined total cost savingsEURAvoided import cost integrated over time (does not include export revenue).Accumulate savings
Combined total levelized cost savingsEURLevelized cost savings totalled across all devices (retro-corrected).Accumulate levelized savings
Combined total financial returnEURFinancial return rate integrated over time.Accumulate financial return
Combined total levelized financial returnEURLevelized financial return totalled across all devices (retro-corrected).Accumulate levelized financial return
Combined levelized totals are derived, not integrated

The levelized totals are computed as the sum of each device's own levelized total (scaled by its correction factor) plus a ledger of removed devices — so editing lifetime values is retroactive and removing a device never drops its historical contribution.


Grid connection​

Import and export both live on the grid device (the single point where they physically happen). See Grid connection configuration.

SensorUnitMeaningEnabled by
Import powerWPower currently bought from the grid.Distribution (W)
Export powerWSurplus power currently sent back to the grid.Distribution (W)
Consumption ratio%Grid import as a share of total home power flow.Distribution ratios
Consumption share%Share of all grid throughput that is import vs. export.Distribution shares
Charging ratio%Share of grid import currently going to battery charging. Only exists when a battery charges from the grid.Distribution ratios · charge source
Charging share%Grid's share of all battery-charging power in the home. Only exists when a battery charges from the grid.Distribution shares · charge source
Standby ratio%Share of grid import currently going to device standby.Distribution ratios
Standby share%Grid's share of all standby power in the home.Distribution shares
Import cost rateEUR/hCurrent cost per hour of grid imports (live price × import power).Cost — Standard
Total import costEURImport cost integrated over time.Accumulate costs
Export compensation rateEUR/hMoney earned per hour from exports (export power × compensation rate).Export compensation rate
Total export compensationEURExport compensation integrated over time.Accumulated export compensation

PV system​

Per PV device. Export sensors require Exports power to grid to be on; levelized sensors require lifetime values (an LCOE). See PV system configuration.

Real-time sensors​

SensorUnitMeaningEnabled by
Export powerWPower from this system currently sent to the grid.Distribution (W) · exports
Export ratio%Fraction of this system's own production currently exported to the grid.Distribution ratios · exports
Export share%This system's share of all power exported by the home.Distribution shares · exports
Self-consumption powerWPower from this system currently consumed in the home.Distribution (W)
Self-consumption ratio%Fraction of this system's own production consumed directly in the home.Distribution ratios
Self-consumption share%This system's share of all self-consumption in the home.Distribution shares
Charging ratio%Share of this system's production currently going to battery charging. Only exists when a battery charges from this system.Distribution ratios · charge source
Charging share%This system's share of all battery-charging power in the home. Only exists when a battery charges from this system.Distribution shares · charge source
Standby ratio%Share of this system's production currently going to device standby.Distribution ratios
Standby share%This system's share of all standby power in the home.Distribution shares
Export compensation rateEUR/hMoney earned per hour exporting this system's power.Export compensation rate · exports
Operating cost rateEUR/hRunning operating cost per hour of this system.Cost — Standard
Levelized operating cost rateEUR/hOperating cost rate using this system's LCOE.Cost — Levelized · has lifetime values
Cost savings rateEUR/hMoney saved per hour by self-consuming this system's power — avoided grid import minus operating costs. Does not include export revenue.Savings — Standard
Levelized cost savings rateEUR/hCost savings rate computed with this system's LCOE.Savings — Levelized · has lifetime values
Financial return rateEUR/hCost savings plus export compensation for this system.Financial return — Standard · exports
Levelized financial return rateEUR/hFinancial return computed with this system's LCOE.Financial return — Levelized · has lifetime values · exports

Accumulated totals​

SensorUnitMeaningEnabled by
Total export compensationEURExport compensation integrated over time.Accumulated export compensation · exports
Total operating costEUROperating cost rate integrated over time.Accumulate costs
Total levelized operating costEURLevelized operating cost integrated (retro-corrected).Accumulate levelized costs · has lifetime values
Total cost savingsEURAvoided import cost integrated over time (does not include export revenue).Accumulate savings
Total levelized cost savingsEURLevelized cost savings integrated (retro-corrected).Accumulate levelized savings · has lifetime values
Total financial returnEURFinancial return rate integrated over time.Accumulate financial return · exports
Total levelized financial returnEURLevelized financial return integrated (retro-corrected).Accumulate levelized financial return · has lifetime values · exports

Battery​

Per battery device. The battery has the same sensor set as a PV system (above) — including cost savings, financial return, and their levelized variants — reading the battery's own values, plus dynamic charging-source sensors. (Its own Charging ratio/share sensors only appear when another battery is configured to charge from this one — battery-to-battery charging — so in most setups they are absent.)

SensorUnitMeaningEnabled by
Charging source shares (one per configured source)%Share of the battery's current charging power coming from each source (e.g. "70 % solar, 30 % grid"). One sensor per source selected in Charges from.Charging source shares

For the battery, the levelized quantities use the battery's LCOS instead of an LCOE. See Battery configuration.


Consumer​

Per consumer device. Consumer support is still under development. See Consumer configuration.

SensorUnitMeaningEnabled by
Consumption share%This consumer's share of all self-consumption in the home.Distribution shares
Power share from <source> (one per source)%Share of this consumer's current power coming from that source (grid / solar / battery). Mirrors the battery's Charging share from <source>.Power source shares
Operating cost rateEUR/hCurrent cost per hour to run this consumer, using the live grid price weighted by its source mix.Cost — Standard
Levelized operating cost rateEUR/hAs above, using each source's levelized cost per kWh.Cost — Levelized